型号
|
GX 1025
|
|
Large high-contrast 3.5 ‘’ TFT colour screen - resolution 320 x 240
|
|
18 direct-access buttons, 1 rotary button
|
Adjustment of signal parameters
|
Continuous adjustment by the encoder and/or numeric keypad
|
BNC output terminals on front panel
|
Generator outputs 1 & 2 - Separate adjustment (waveform, f, phase, amplitude, etc.), coupled or duplicated
|
BNC I/O terminals on rear panel
|
TTL-compatible trigger and synchronization outputs
|
Signal types
|
Sine, Square, Triangle, Ramp, Pulse, White Noise, Arbitrary Signal (48 pre-installed waveforms)
|
Resolution / Sampling rate
|
14 bits / 125 MS/s
|
Memory
|
16k memory depth (512k on CH1 only) - Storage of predefined or specific signals on USB key
|
Editing of signals with SX-GENE
|
Acquisition, transfer & modification of a signal acquired from an oscilloscope (OX6000, OX7000, Scopein@Box) Graphical or mathematical editing with the SX-GENE software Modification of a signal acquired and/or combination of standard signals from the generator
|
Frequency range
|
Sine from 0.001 mHz to 25.000 MHz,Triangle 300 kHz, Noise and Square 25 MHz, Pulse 10 MHz, Arbitrary Signals 5 MHz
|
Resolution / accuracy
|
7-digit display – resolution from 1 mHz to 1 kHz depending on frequency range ± 20 ppm for F > 10 kHz , ± 30 ppm for F < 10 kHz
|
Long-term drift
|
± 100 ppm / year
|
Temperature coefficient
|
< 5 ppm / °C
|
Voltage levels
|
Output 1 = 2 mVpp ~ 10 Vpp 50 Ω 2 mVpp ~ 20 Vpp open circuit
Output 2 = 2 mVpp ~ 3 Vpp 50 Ω 2 mVpp ~ 6 Vpp open circuit
|
Flatness
|
< 0.1 dB for f < 100 kHz
|
Vdc offset
|
Output 1 = ± 5 VDC at 50 Ω, Output 2 = 1,5 VDC at 50 Ω – accuracy < 5% ±1 mV
|
Impedance / Protection
|
50 Ω / Protection contre les court-circuits
|
Sine
|
Distortion < 0.2 % typical for f < 20 kHz, and harmonics < -50 dBc for DC < f < 25 MHz (level < 1 Vpp)
|
Triangle (max frequency 2 MHz)
|
Linearity error < 1% max
|
Square & pulse
|
Rise time < 12 ns (typ.) – Duty cycle 20-80% (DC < f < 20 MHz) – Pulse 20 ns to 2,000 s
|
Measurement range / resolution
|
100 mHz to 200 MHz
|
Sensitivity / Input impedance
|
20 mVrms for 100 mHz < f < 100 MHz, 40 mVrms beyond / 1 MΩ
|
Storage
|
Storage of predefined or specific signals and complete instrument configurations
|
Communication interface
|
USB Device, USB host - GPIB, LAN option
|
Mains power supply
|
100~240 VACRMS 45~440 Hz CAT I - < 30W
|
Software
|
The SX-GENE software can be downloaded free of charge from our support website, along with the LV and LW drivers
|
Mechanical specifications
|
L x H x P = 229 mm x 105 mm x 281 mm - 2.8 kg
|
Warranty
|
1 year
|